Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Product Categories
Send Inquiry
Payment Type: L/C,T/T,Paypal
$18600
1-2 Set/Sets
$17900
3-9 Set/Sets
$16500
≥10 Set/Sets
Model | |
Types | |
filter material | |
option | |
Contact Now |
Model No.: LVF-50
Brand: Loren
Applicable Industry: Food &Amp; Beverage Shops, Manufacturing Plant, Construction Works, Food &Amp; Beverage Factory, Energy &Amp; Mining
Out-of-warranty Service: Video Technical Support, Online Support, Spare Parts, Field Maintenance And Repair Service
Video Factory Inspection: Provided
Mechanical Test Report: Provided
Marketing Type: Ordinary Product
Core Component Warranty Period: 1 Year
Core Components: Pressure Vessel
Old And New: New
Place Of Origin: China
Warranty Period: 1 Year
Service System: Online Support
Auto Filtration: By Gravity
NO: Valve
Little Consumption: Energy and cost and operator
Design: Customized and Diversified shape
OEM ,ODM: Service Available
Water Head Lost: about 1700mm Range
Can Be Combined: In group or containerized
Management And Maintenance: Easy
Integarated With: Inlet and outlet Water Tanks and Pipels
No: Site Operartor
Steel Gravity Valveless Filter
Description
Gravity Valveless Filter Is An Ideal Water Treatment Filtration Equipment
Principle
Tap Water Flow into the Filter and Separate Impurities from the water Through its Media Layers From Up To Down Via Gravity By Siphon Phenomenon Because Of Negative Pressure Thus To Generate Auto Back Washing To Make The System As a Filtration Cycle .
Feature
-No Valve and Control Valve
-No Need Site Operator Working
-Lower Energy Consumption
-Lower Running Cost
-Safe and Reliable Running
-Easy Management
-Compact design Integration Water Tanks and U-sharp Pipes
- High Precise Processing with Coating
Applicant
-Bypass Filter Treatment of Such Industrial Circulation Water as Petroleum, Chemical Industry, Metallurgy, Electric Power, Oil Refining, Light Industry&Textile
- Surface Water Purifying
-Iron & Manganese Removal of Underground Water
-Waterworks Plant Water Filtration
-Preliminary Treatment for Water Softening and Desalination
-Swimming Pool Water Purification
-Landscape Waste Water Purification
-TSS Removal of Production Line Waste Water
- Further Purification after Secondary Sewage Treatment
Model Selection
A. Circular Shape Group Model Parameter
Item | Model | ||||
LVF-20 | LVF-40 | LVF-60 | LVF-80 | ||
Capacity (M3/H) | 20 | 40 | 60 | 80 | |
Outline size(m) | L | 3600 | 4400 | 5400 | 5900 |
W | 2100 | 2500 | 3000 | 3200 | |
H | 6800 | 6800 | 6800 | 6800 | |
Tube size (mm) | Inlet DN Dg1 | 100 | 150 | 200 | 200 |
Height H1 | 4710 | 4810 | 4810 | 4810 | |
Out let DN Dg2 | 100 | 150 | 150 | 200 | |
Height H2 | 400 | 450 | 500 | 500 | |
Drain tube DN Dg3 | 300 | 300 | 400 | 400 | |
Height H3 | 360 | 360 | 460 | 460 | |
Tube pot size (mm) | Ø1 | 1400 | 1800 | 2240 | 2460 |
Ø2 | 900 | 1000 | 1000 | 1000 | |
c | 1134 | 1350 | 1540 | 1636 | |
e | 655 | 780 | 890 | 945 | |
f | 755 | 950 | 1125 | 1225 | |
g | 215 | 250 | 325 | 355 | |
Weight(Metric Tons ) | 21.9 | 35.7 | 50.6 | 65.7 |
B. Rectangular Shape Group Model Parameter
Each unit With Two Square Shape Tank With Finish Water Lost:1700mm | |||||
Model | Volume/ Filter Area (m3/h*m2) | Body Dimension | G.W. | Media Volume /Weight(m³/T) | Backwash Flow 15L/m²·S |
LVF20-1 | 20/2.13 | 2000×1100×4340 | 16.2 | 2.07/3.62 | 18.75 |
LVF30-1 | 30/3.19 | 2000×1630×4402 | 23.1 | 3.09/5.42 | 28.03 |
LVF40-1 | 40/4.24 | 2165×2000×4442 | 29.9 | 4.11/7.20 | 37.40 |
LVF50-1 | 50/5.33 | 2710×2000×4442 | 36.5 | 5.17/9.05 | 46.88 |
LVF60-1 | 60/6.39 | 2600×2500×4502 | 44.2 | 6.20/10.85 | 56.25 |
LVF80-1 | 80/8.50 | 3600×2900×4547 | 58.8 | 8.25/14.43 | 75.00 |
LVF100-1 | 100/10.52 | 2100×2600×4512 | 37.7 | 10.2/17.86 | 93.90 |
LVF1251 | 125/13.13 | 2255×3000×4558 | 46.4 | 12.74/22.29 | 116.98 |
LVF150-1 | 150/15.67 | 2705×3000×4558 | 54.7 | 15.20/26.60 | 139.52 |
LVF175-1 | 175/18.40 | 3160×3000×4558 | 63.3 | 17.85/31.23 | 163.50 |
C. Filter Media Capacity
Model | Quartz DN | Gravel Cushion Grain DN | ||
1~2mm | 2~4mm | 4~8mm | 8~16mm | |
LVF-20 | 2.7 | 0.24 | 0.24 | 0.35 |
LVF-40 | 4.7 | 0.42 | 0.42 | 0.60 |
LVF-60 | 7.3 | 0.63 | 0.63 | 0.95 |
LVF-80 | 9.0 | 0.80 | 0.80 | 1.15 |
Supply & Install Range
-Filter Body Includes All Inside Parts.
-Filter Outer Parts Like Siphon& Drainage Water Tubes as well as Tube Supports
-The Connecting Pipeline, Valves & Supports Among Same Group Filter Tanks.
-Steel Filter Drain Clean Valves, Short Pipes And Elbows.
Media & Support Media Arrangement Method
- Clean All Impurities After Mounting The Filter, Then Mark Each Proof Height Line Of Each Media And Support Media In Filter Inner Wall, Double Check Each Grain Dn Range To Fill Them From Large To Small For Real Distribution.
- Carry On Support Media Arrangement From Bottom Average-Thickness Support Media (Material) To Upper In Line With All Formal Marked Line.
- After Finishing Support Media Arrangement, Then Distribute Filter Media Same As Before Carefully To Make Sure Its Proportionate Arrangement In Line With Marked Line By Adjusting Them With Blade.
Mounting Description
- When Put Filter Into Site Position, Must Check Level Again To Make It Mounted Smooth And Stable, It Will Be Welded Into The Bottom Steel Plates And Fixed.
- Water Tank Bolted With Filter Roof Beam Support To Make Two Weirs Into Same Level Height Thus To Safeguard The Water Distribution Averagely.
- Connecting Flange And Screw With Siphon Tube System Must No Air Leakage And Strictly Control The Height Of Siphon And Auxiliary Tube Proof Position.
- Besides Special Inside Corrosion-Proof Treatment, The Outside Surface Also Need Do Color Stipulated Coating.
Operation Description
- First Running, Use Rubber Tube To Inject Clean Water Into Water Tank To Make Water
Going Through Filter From Bottom To Upper Via Connecting Tube To Drain Out The Air In Filter.
- First Back washing , Adjust The Washing Intensity Into 1/4 Of The Siphon Reduce Tube DN Position Via Intensity Adjusting Device , After That , Increase The Opening Degree Gradually Till Regulated Value.
- During Operation, Must Check If Its Filter Media In Level Position Or Being Polluted Esp. When As By Pass Filtering Circulated Cooling Water Whose Filter Media Is Easy To Be Polluted By Algae, If Found , Must Remove The Polluted Media Layer Around 100mm Thickness And Then Change It As New Filter Media.
Packaging: poly or wooden or customized
Productivity: 25 Sets Per Month
Place of Origin: China
Supply Ability: 25 sets per month
Certificate: Iso 9001:2015
HS Code: 8421219990
Port: SHANGHAI,NINGBO,Qingdao
Payment Type: L/C,T/T,Paypal
Incoterm: FOB,CFR,CIF,EXW,FAS,FCA,CPT,CIP,DDP,DDU,DEQ,Express Delivery
GET IN TOUCH
If you have any questions our products or services,feel free to reach out to us.Provide unique experiences for everyone involved with a brand.we’ve got preferential price and best-quality products for you.
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.